Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
ACS Omega ; 9(14): 16800-16809, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38617682

RESUMO

In the past 5 years, real-time health monitoring has become ubiquitous with the development of watches and rings that can measure and report on the physiological state. As an extension, real-time biomarker sensors, such as the continuous glucose monitor, are becoming popular for both health and performance monitoring. However, few real-time sensors for biomarkers have been made commercially available; this is primarily due to problems with cost, stability, sensitivity, selectivity, and reproducibility of biosensors. Therefore, simple, robust sensors are needed to expand the number of analytes that can be detected in emerging and existing wearable platforms. To address this need, we present a simple but novel sensing material. In short, we have modified the already popular PEDOT/PSS conductive polymer by completely removing the PEDOT component and thus have fabricated a polystyrene sulfonate (PSS) sensor electrodeposited on a glassy carbon (GC) base (GC-PSS). We demonstrate that coupling the GC-PSS sensor with differential pulse voltammetry creates a sensor capable of the selective and sensitive detection of serotonin. Notably, the GC-PSS sensor has a sensitivity of 179 µA µM-1 cm-2 which is 36x that of unmodified GC and an interferent-free detection limit of 10 nM, which is below the concentrations typically found in saliva, urine, and plasma. Notably, the redox potential of serotonin interfacing with the GC-PSS sensor is at -0.188 V versus Ag/AgCl, which is significantly distanced from peaks produced by common interferants found in biofluids, including serum. Therefore, this paper reports a novel, simple sensor and polymeric interface that is compatible with emerging wearable sensor platforms.

2.
Biosensors (Basel) ; 13(6)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37366999

RESUMO

The current COVID-19 pandemic has highlighted the power, speed, and simplicity of point-of-care (POC) diagnostics. POC diagnostics are available for a wide range of targets, including both drugs of abuse as well as performance-enhancing drugs. For pharmacological monitoring, minimally invasive fluids such as urine and saliva are commonly sampled. However, false positives or negatives caused by interfering agents excreted in these matrices may confound results. For example, false positives have, in most cases, prevented the use of POC diagnostics for pharmacological agent detection; the consequence is that centralized labs are instead tasked to perform these screenings, resulting in significant delays between sampling and testing. Thus, a rapid, simple, and inexpensive methodology for sample purification is required for the POC to reach a field-deployable tool for the pharmacological human health and performance assessments. Buffer exchange is a simple, rapid approach to remove interfering agents, but has traditionally been difficult to perform on small pharmacological molecules. Therefore, in this communication, we use salbutamol, a performance-enhancing drug, as a case example to demonstrate the efficacy of ion-exchange chromatography as a technique to perform buffer exchange for charged pharmacological agents. This manuscript demonstrates the efficacy of this technique leveraging a commercial spin column to remove interfering agents found in simulant urines, such as proteins, creatinine, and urea, while retaining salbutamol. The utility and efficacy of the method was then confirmed in actual saliva samples. The eluent was then collected and run on the lateral flow assays (LFAs), improving the reported limit of detection by over 5× (new lower limit of detection of 10 ppb compared to reported 60 ppb by the manufacturer) while simultaneously removing noise due to background interfering agents.


Assuntos
COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , COVID-19/diagnóstico , Pandemias , Testes Imediatos , Cromatografia Líquida de Alta Pressão
3.
ACS Sens ; 8(2): 610-618, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36657059

RESUMO

Inhaled medications are commonplace for administering bronchodilators, anticholinergics, and corticosteroids. While they have a defined legitimate use, they are also used in sporting events as performance-enhancing drugs. These performance enhancers can be acquired via both legal (i.e., at a pharmacy through over-the-counter medications or through a prescription) and illicit (i.e., black market and foreign pharmacies) means, thus making monitoring procurement impossible. While urine tests can detect these pharmacological agents hours after they have been inhaled, there is a significant lag time before they are observed in urine. Direct detection of these inhaled agents is complicated and requires a multiplexed approach due to the sheer number of inhaled pharmacological agents. Therefore, detection of propellants, which carry the drug into the lungs, provides a simpler path forward toward detection of broad pharmacological agents. In this paper, we demonstrate the first use of terahertz spectroscopy (THz) to detect inhaled medications in human subjects. Notably, we were able to detect and quantitate the propellant, HFA-134a, in breath up to 30 min after using an asthma inhaler, enabling the use of a point-of-care device to monitor exhaled breath for the presence of propellants. We also demonstrate via simulations that the same approach can be leveraged to detect and identify next-generation propellants, specifically HFA-152a. As a result, we provide evidence that a single point-of-care THz sensor can detect when individuals have used pressure-mediated dose inhalers (pMDIs) without further modification of the hardware.


Assuntos
Asma , Espectroscopia Terahertz , Humanos , Propelentes de Aerossol/uso terapêutico , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Broncodilatadores/química , Broncodilatadores/uso terapêutico
4.
Biosens Bioelectron ; 211: 114374, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35605548

RESUMO

There is an increased demand for real-time monitoring of biological and biochemical processes. While most sensor research focuses on physiological conditions, less has been done towards developing real-time biosensors that can operate in and survive exposure to extreme environments and harsh chemicals such as fuel. One interesting application is monitoring microbial load in fuel tanks to prevent both fuel spoilage and biocorrosion. We developed a comprehensive method to enable the first reagentless, real-time, microbial sensor platform that is also fuel resistant. We first identified an extracellular protein epitope conserved in fuel-degrading fungi then used this epitope to develop a suitable biorecognition element (BRE) through biopanning of a 7-mer phage displayed peptide library. After demonstrating the BRE's affinity to fungi using molecular and fluorescence assays, we incorporated the BRE into a reagentless, real-time electrochemical sensing platform based on a self-assembled monolayer of peptide BREs and redox reporters. Finally, we incorporated this real-time electrochemical sensing platform into a microfluidic device. We demonstrated detection of Yarrowia lipolytica as low as 1 × 104 CFU/mL in a bath cell, and demonstrate a microfluidic cell that functions even after exposure to jet fuel. In summary, this work describes development of a fuel-resistant biosensor for monitoring microbial growth in extreme environments.


Assuntos
Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , Epitopos , Dispositivos Lab-On-A-Chip , Microfluídica , Biblioteca de Peptídeos
5.
Adv Mater Interfaces ; 9(18): 2102209, 2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35538926

RESUMO

Multiplex electronic antigen sensors for detection of SARS-Cov-2 spike glycoproteins and hemagglutinin from influenza A are fabricated using scalable processes for straightforward transition to economical mass-production. The sensors utilize the sensitivity and surface chemistry of a 2D MoS2 transducer for attachment of antibody fragments in a conformation favorable for antigen binding with no need for additional linker molecules. To make the devices, ultra-thin layers (3 nm) of amorphous MoS2 are sputtered over pre-patterned metal electrical contacts on a glass chip at room temperature. The amorphous MoS2 is then laser annealed to create an array of semiconducting 2H-MoS2 transducer regions between metal contacts. The semiconducting crystalline MoS2 region is functionalized with monoclonal antibody fragments complementary to either SARS-CoV-2 S1 spike protein or influenza A hemagglutinin. Quartz crystal microbalance experiments indicate strong binding and maintenance of antigen avidity for antibody fragments bound to MoS2. Electrical resistance measurements of sensors exposed to antigen concentrations ranging from 2-20 000 pg mL-1 reveal selective responses. Sensor architecture is adjusted to produce an array of sensors on a single chip suited for detection of analyte concentrations spanning six orders of magnitude from pg mL-1 to µg mL-1.

6.
Adv Sci (Weinh) ; 9(7): e2104426, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35023321

RESUMO

Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various occupational sectors, such as industry, academy, sports, recreation, and military. While various commercially wearable sensors are on the market with their capability of "quantitative assessments" on human health, physical, and psychological states, their sensing is mostly based on physical traits, and thus lacks precision in HHPM. Minimally or noninvasive biomarkers detectable from the human body, such as body fluid (e.g., sweat, tear, urine, and interstitial fluid), exhaled breath, and skin surface, can provide abundant additional information to the HHPM. Detecting these biomarkers with novel or existing sensor technologies is emerging as critical human monitoring research. This review provides a broad perspective on the state of the art biosensor technologies for HHPM, including the list of biomarkers and their physiochemical/physical characteristics, fundamental sensing principles, and high-performance sensing transducers. Further, this paper expands to the additional scope on the key technical challenges in applying the current HHPM system to the real field.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Biomarcadores , Humanos , Monitorização Fisiológica , Suor
7.
Sensors (Basel) ; 21(23)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34884067

RESUMO

Electrochemical biosensors promise a simple method to measure analytes for both point-of-care diagnostics and continuous, wearable biomarker monitors. In a liquid environment, detecting the analyte of interest must compete with other solutes that impact the background current, such as redox-active molecules, conductivity changes in the biofluid, water electrolysis, and electrode fouling. Multiple methods exist to overcome a few of these challenges, but not a comprehensive solution. Presented here is a combined boron-doped diamond electrode and oil-membrane protection approach that broadly mitigates the impact of biofluid interferents without a biorecognition element. The oil-membrane blocks the majority of interferents in biofluids that are hydrophilic while permitting passage of important hydrophobic analytes such as hormones and drugs. The boron-doped diamond then suppresses water electrolysis current and maintains peak electrochemical performance due to the foulant-mitigation benefits of the oil-membrane protection. Results show up to a 365-fold reduction in detection limits using the boron-doped diamond electrode material alone compared with traditional gold in the buffer. Combining the boron-doped diamond material with the oil-membrane protection scheme maintained these detection limits while exposed to human serum for 18 h.


Assuntos
Técnicas Biossensoriais , Boro , Eletrodos , Eletrólise , Humanos , Água
8.
ACS Appl Mater Interfaces ; 13(45): 53553-53563, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34665962

RESUMO

To take full advantage of the reagent- and label-free sensing capabilities of electrochemical sensors, a frequent and remaining challenge is interference and degradation of the sensors due to uncontrolled pH or salinity in the sample solution or foulants from the sample solution. Here, we present an oil-membrane sensor protection technique that allows for the permeation of hydrophobic (lipophilic) analytes into a sealed sensor compartment containing ideal salinity and pH conditions while simultaneously blocking common hydrophilic interferents (proteins, acids, bases, etc.) In this paper, we validate the oil-membrane sensor protection technique by demonstrating continuous cortisol detection via electrochemical aptamer-based (EAB) sensors. The encapsulated EAB cortisol sensor exhibits a 5 min concentration-on rise time and maintains a measurement signal of at least 7 h even in the extreme condition of an acidic solution of pH 3.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Técnicas Eletroquímicas , Hidrocortisona/análise , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas
9.
Sensors (Basel) ; 20(8)2020 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-32316211

RESUMO

Real-time sensing of proteins, especially in wearable devices, remains a substantial challenge due to the need to convert a binding event into a measurable signal that is compatible with the chosen analytical instrumentation. Impedance spectroscopy enables real-time detection via either measuring electrostatic interactions or electron transfer reactions while simultaneously being amenable to miniaturization for integration into wearable form-factors. To create a more robust methodology for optimizing impedance-based sensors, additional fundamental studies exploring components influencing the design and implementation of these sensors are needed. This investigation addresses a sub-set of these issues by combining optical and electrochemical characterization to validate impedance-based sensor performance as a function of (1) biorecognition element density, (2) self-assembled monolayer chain length, (3) self-assembled monolayer charge density, (4) the electrochemical sensing mechanism and (5) the redox reporter selection. Using a pre-existing lysozyme aptamer and lysozyme analyte combination, we demonstrate a number of design criteria to advance the state-of-the-art in protein sensing. For this model system we demonstrated the following: First, denser self-assembled monolayers yielded substantially improved sensing results. Second, self-assembled monolayer composition, including both thickness and charge density, changed the observed peak position and peak current. Third, single frequency measurements, while less informative, can be optimized to replace multi-frequency measurements and in some cases (such as that with zwitterionic self-assembled monolayers) are preferred. Finally, various redox reporters traditionally not used in impedance sensing should be further explored. Collectively, these results can help limit bottlenecks associated with device development, enabling realization of next-generation impedance-based biosensing with customize sensor design for the specific application.


Assuntos
Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica/métodos , Aptâmeros de Peptídeos/química , Técnicas Biossensoriais/instrumentação , Brometos/síntese química , Brometos/metabolismo , Espectroscopia Dielétrica/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Desenho de Equipamento , Azul de Metileno/química , Muramidase/análise , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/metabolismo , Compostos de Sulfidrila/química , Compostos de Sulfidrila/metabolismo
10.
J Breath Res ; 14(3): 036004, 2020 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-32155613

RESUMO

The Respiration Collector for In Vitro Analysis (ReCIVA) sampler, marketed by Owlstone Medical, provides a step forward in exhaled breath sampling through active sampling directly onto thermal desorption (TD) tubes. Although an improvement to the issues surrounding breath bag sampling, the ReCIVA device, first released in 2015, is a relatively new research and clinical tool that requires further exploration. Here, data are presented comparing two distinct ReCIVA devices. The results, comparing ReCIVA serial numbers #33 and #65, demonstrate that overall statistically insignificant results are obtained via targeted isoprene quantitation (p > 0.05). However, when the data are parsed by the TD tube type used to capture breath volatiles, either Tenax TA or the dual bed Tenax/Carbograph 5TD (5TD), a statistical difference (p < 0.05) among the two different TD tubes was present. These data, comparing the two ReCIVA devices with both Tenax TA and 5TD tubes, are further supported by a global metabolomics analysis yielding 85% of z-scores, comparing ReCIVA devices, below the limit for significance. Experiments to determine the effect of breathing rate on ReCIVA function, using guided breathing for low (7.5 breaths min-1) and high (15 breaths min-1) breathing rates, demonstrate the ReCIVA device shows no statistical difference among breathing rates for quantitated isoprene (p > 0.05). Global metabolomics analysis of the guided breathing rate data shows more than 87% of the z-scores, comparing high and low breathing rates using both the Tenax and the 5TD tubes, are below the level for significance. Finally, data are provided from a single participant who displayed background levels of isoprene while illustrating levels of acetone consistent with the remaining participants. Collectively, these data support the use of multiple ReCIVA devices for exhaled breath collection and provide evidence for an instance where exhaled isoprene is consistent with background levels.


Assuntos
Testes Respiratórios/instrumentação , Manejo de Espécimes/instrumentação , Temperatura , Butadienos/análise , Expiração , Hemiterpenos/análise , Humanos , Masculino , Padrões de Referência , Compostos Orgânicos Voláteis/análise
11.
ACS Sens ; 5(1): 13-18, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31833351

RESUMO

Environmental hazards typically are encountered in the gaseous phase; however, selective sensing modalities for identifying and quantitating compounds of interest in an inexpensive, pseudo-real-time format are severely lacking. Here, we present a novel proof-of-concept that combines an Air2Liquid sampler in conjunction with an oil-in-water microfluidic assay for detection of organophosphates. We believe this proof-of-concept will enable development of a new platform technology for semivolatile detection that we have demonstrated to detect 50 pmoles (2 ppb) of neurotoxic organophosphates.


Assuntos
Técnicas Biossensoriais/métodos , Gases/química , Organofosfatos/metabolismo
12.
J Breath Res ; 14(1): 016009, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31703231

RESUMO

Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.


Assuntos
Testes Respiratórios/métodos , Butadienos/análise , Calibragem , Expiração , Hemiterpenos/análise , Humanos , Masculino , Padrões de Referência , Siloxanas/química , Manejo de Espécimes
13.
Acc Chem Res ; 52(2): 297-306, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30688433

RESUMO

Physiological sensors in a wearable form have rapidly emerged on the market due to technological breakthroughs and have become nearly ubiquitous with the Apple Watch, FitBit, and other wearable devices. While these wearables mostly monitor simple biometric signatures, new devices that can report on the human readiness level through sensing molecular biomarkers are critical to optimizing the human factor in both commercial sectors and the Department of Defense. The military is particularly interested in real-time, wearable, minimally invasive monitoring of fatigue and human performance to improve the readiness and performance of the war fighter. However, very few devices have ventured into the realm of reporting directly on biomarkers of interest. Primarily this is because of the difficulties of sampling biological fluids in real-time and providing accurate readouts using highly selective and sensitive sensors. When additional restrictions to only use sweat, an excretory fluid, are enforced to minimize invasiveness, the demands on sensors becomes even greater due to the dilution of the biomarkers of interest, as well as variability in salinity, pH, and other physicochemical variables which directly impact the read-out of real-time biosensors. This Account will provide a synopsis not only on exemplary demonstrations and technological achievements toward implementation of real-time, wearable sweat sensors but also on defining problems that still remain toward implementation in wearable devices that can detect molecular biomarkers for real world applications. First, the authors describe the composition of minimally invasive biofluids and then identify what biomarkers are of interest as biophysical indicators. This Account then reviews demonstrated techniques for extracting biofluids from the site of generation and transport to the sensor developed by the authors. Included in this discussion is a detailed description on biosensing recognition elements and transducers developed by the authors to enable generation of selective electrochemical sensing platforms. The authors also discuss ongoing efforts to identify biorecognition elements and the chemistries necessary to enable high affinity, selective biorecognition elements. Finally, this Account presents the requirements for wearable, real-time sensors to be (1) highly stable, (2) portable, (3) reagentless, (4) continuous, and (5) responsive in real-time, before delving into specific methodologies to sense classes of biomarkers that have been explored by academia, government laboratories, and industry. Each platform has its areas of greatest utility, but also come with corresponding weaknesses: (1) ion selective electrodes are robust and have been demonstrated in wearables but are limited to detection of ions, (2) enzymatic sensors enable indirect detection of metabolites and have been demonstrated in wearables, but the compounds that can be detected are limited to a subset of small molecules and the sensors are sensitive to flow, (3) impedance-based sensors can detect a wide range of compounds but require further research and development for deployment in wearables. In conclusion, while substantial progress has been made toward wearable molecular biosensors, substantial barriers remain and need to be solved to enable deployment of minimally invasive, wearable biomarker monitoring devices that can accurately report on psychophysiological status.


Assuntos
Biomarcadores/análise , Técnicas Biossensoriais/métodos , Monitorização Fisiológica/métodos , Suor/química , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Humanos , Monitorização Fisiológica/instrumentação
14.
PLoS One ; 14(1): e0210286, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30650158

RESUMO

Insurmountable detection challenges will impede the development of many of the next-generation of lab-on-a-chip devices (e.g., point-of-care and real-time health monitors). Here we present the first membrane-based, microfluidic sample preconcentration method that is continuous, quantifiable, simple, and capable of working with any analyte. Forward osmosis rapidly concentrates analytes by removing water from a stream of sample fluid. 10-100X preconcentration is possible in mere minutes. This requires careful selection of the semi-permeable membrane and draw molecule; therefore, the osmosis performance of several classes of membranes and draw molecules were systematically optimized. Proof-of-concept preconcentration devices were characterized based on their concentration ability and fouling resistance. In-silico theoretical modeling predicts the experimental findings and provides an engineering toolkit for future designs. With this toolkit, inexpensive ready-for-manufacturing prototypes were also developed. These devices provide broad-spectrum detection improvements across many analytes and sensing modalities, enabling next-generation lab-on-a-chip devices.


Assuntos
Dispositivos Lab-On-A-Chip , Animais , Bovinos , Simulação por Computador , Desenho de Equipamento , Glucose/análise , Humanos , Membranas Artificiais , Osmose , Porosidade , Soroalbumina Bovina/análise
15.
PLoS One ; 13(7): e0200009, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30011292

RESUMO

Non-invasive wearable biosensors provide real-time, continuous, and actionable health information. However, difficulties detecting diluted biomarkers in excreted biofluids limit practical applications. Most biomarkers of interest are transported paracellularly into excreted biofluids from biomarker-rich blood and interstitial fluid during normal modulation of cellular tight junctions. Calcium chelators are reversible tight junction modulators that have been shown to increase absorption across the intestinal epithelium. However, calcium chelators have not yet been shown to improve the extraction of biomarkers. Here we show that for glucose, a paracellularly transported biomarker, the flux into sweat can be increased by >10x using citrate, a calcium chelator, in combination with electroosmosis. Our results demonstrate a method of increasing glucose flux through the sweat gland epithelium, thereby increasing the concentration in sweat. Future work should examine if this method enhances flux for other paracellularly transported biomarkers to make it possible to detect more biomarkers with currently available biosensors.


Assuntos
Glucose/metabolismo , Glândulas Sudoríparas/metabolismo , Suor/metabolismo , Transporte Biológico/efeitos dos fármacos , Técnicas Biossensoriais , Citratos/farmacologia , Relação Dose-Resposta a Droga , Eletro-Osmose , Feminino , Humanos , Masculino , Permeabilidade/efeitos dos fármacos , Glândulas Sudoríparas/citologia , Glândulas Sudoríparas/efeitos dos fármacos , Adulto Jovem
16.
ACS Sens ; 3(5): 1024-1031, 2018 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-29741092

RESUMO

Sensors for human health and performance monitoring require biological recognition elements (BREs) at device interfaces for the detection of key molecular biomarkers that are measurable biological state indicators. BREs, including peptides, antibodies, and nucleic acids, bind to biomarkers in the vicinity of the sensor surface to create a signal proportional to the biomarker concentration. The discovery of BREs with the required sensitivity and selectivity to bind biomarkers at low concentrations remains a fundamental challenge. In this study, we describe an in-silico approach to evolve higher sensitivity peptide-based BREs for the detection of cardiac event marker protein troponin I (cTnI) from a previously identified BRE as the parental affinity peptide. The P2 affinity peptide, evolved using our in-silico method, was found to have ∼16-fold higher affinity compared to the parent BRE and ∼10 fM (0.23 pg/mL) limit of detection. The approach described here can be applied towards designing BREs for other biomarkers for human health monitoring.


Assuntos
Técnicas Biossensoriais/métodos , Peptídeos/química , Sequência de Aminoácidos , Biomarcadores/análise , Dicroísmo Circular , Simulação por Computador , Espectroscopia Dielétrica , Humanos , Imunoensaio , Limite de Detecção , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície , Troponina I/química
17.
ACS Omega ; 3(6): 6230-6236, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-31458805

RESUMO

Breathing-air quality within commercial airline cabins has come under increased scrutiny because of the identification of volatile organic compounds (VOCs) from the engine bleed air used to provide oxygen to cabins. Ideally, a sensor would be placed within the bleed air pipe itself, enabling detection before it permeated through and contaminated the entire cabin. Current gas-phase sensors suffer from issues with selectivity, do not have the appropriate form factor, or are too complex for commercial deployment. Here, we chose isopropyl alcohol (IPA), a main component of de-icer spray used in the aerospace community, as a target analyte: IPA exposure has been hypothesized to be a key component of aerotoxic syndrome in pre, during, and postflight. IPAs proposed mechanism of action is that of an anesthetic and central nervous system depressant. In this work, we describe IPA sensor development by showing (1) the integration of a polymer as an IPA capture matrix, (2) the adoption of a redox chemical additives as an IPA oxidizer, and (3) the application of carbon nanotubes as an electronic sensing conduit. We demonstrate the ability to not only detect IPA at 100-10 000 ppm in unfiltered, laboratory air but also discriminate among IPA, isoprene, and acetone, especially in comparison to a typical photoionization detector. Overall, we show an electronic device that operates at room temperature and responds preferentially to IPA, where the increase in the resistance corresponds directly to the concentration of IPA. Ultimately, this study opens up the pathway to selective electronic sensors that can enable real-time monitoring in a variety of environments for the force health prevention and protection, and the potential through future work to enable low parts-per-million and possibly high parts-per-billion selective detection of gas-phase VOCs of interest.

18.
Protein Sci ; 26(3): 497-504, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27977897

RESUMO

Membrane localization domain (MLD) was first proposed for a 4-helix-bundle motif in the crystal structure of the C1 domain of Pasteurella multocida toxin (PMT). This structure motif is also found in the crystal structures of several clostridial glycosylating toxins (TcdA, TcdB, TcsL, and TcnA). The Ras/Rap1-specific endopeptidase (RRSP) module of the multifunctional autoprocessing repeats-in-toxins (MARTX) toxin produced by Vibrio vulnificus has sequence homology to the C1-C2 domains of PMT, including a putative MLD. We have determined the solution structure for the MLDs in PMT and in RRSP using solution state NMR. We conclude that the MLDs in these two toxins assume a 4-helix-bundle structure in solution.


Assuntos
Proteínas de Bactérias/química , Toxinas Bacterianas/química , Membrana Celular/química , Pasteurella multocida/química , Vibrio vulnificus/química , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Toxinas Bacterianas/genética , Toxinas Bacterianas/metabolismo , Membrana Celular/genética , Membrana Celular/metabolismo , Pasteurella multocida/genética , Pasteurella multocida/metabolismo , Domínios Proteicos , Estrutura Secundária de Proteína , Homologia de Sequência de Aminoácidos , Vibrio vulnificus/genética , Vibrio vulnificus/metabolismo
19.
Langmuir ; 32(48): 12656-12663, 2016 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-27934511

RESUMO

Electrowetting and electrocapillarity of liquid metals have a long history, and a recent explosion of renewed interest. Liquid metals have electromagnetic properties and surface tensions (>500 mN/m) that enable new forms of reconfigurable devices. However, the only nontoxic option, gallium alloys, suffer from immediate formation of a semirigid surface oxide. Although acids or electrochemical reduction can remove this oxide, these approaches surround the gallium alloy in a fluid that is also electrically conducting, diminishing electromagnetic effectiveness and precluding electrowetting actuation. Reported here are acidified siloxanes that remove and prevent oxide formation. Importantly, the siloxane oil associatively incorporates hydrochloric or hydrobromic acids, is electrically insulating, is chemically stable, removes etching byproducts (including water), and allows robust electrowetting. This work opens up new opportunities for liquid metal reconfiguration, and is of fundamental interest due to the unexpected chemical stability of the acidified siloxanes and their application to other materials and surfaces.

20.
Biomol NMR Assign ; 8(1): 221-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23765284

RESUMO

(1)H, (13)C, and (15)N chemical shift assignments are presented for the isolated four-helical bundle membrane localization domain (MLD) from Pasteurella multocida toxin (PMT) in its solution state. We have assigned 99% of all backbone and side-chain carbon atoms, including 99% of all backbone residues excluding proline amide nitrogens. Secondary chemical shift analysis using TALOS+ demonstrates four helices, which align with those observed within the MLD in the crystal structure of the C-terminus of PMT (PDB 2EBF) and confirm the use of the available crystal structures as templates for the isolated MLDs.


Assuntos
Proteínas de Bactérias/química , Toxinas Bacterianas/química , Membrana Celular/química , Ressonância Magnética Nuclear Biomolecular , Pasteurella multocida/metabolismo , Sequência de Aminoácidos , Dados de Sequência Molecular , Estrutura Terciária de Proteína
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...